Waterproof Portable EC/TDS/Resistivity/Salinity Meter - HI98192

Sku: HI98192

Waterproof Portable EC/TDS/Resistivity/Salinity Meter - HI98192

Sku: HI98192
Product not available for online purchase

Waterproof Portable EC/TDS/Resistivity/Salinity Meter - HI98192

The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.

  • Four Ring Probe
  • Quick Connect
  • Ergonomic, One-Handed Operation
SKUHI98192
Product NameWaterproof Portable EC/TDS/Resistivity/Salinity Meter - HI98192
Quote RequiredNo
EC Range0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibrationautomatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
EC/TDS Temperature CompensationnoTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Temperature Correction Coefficient0.00 to 10.00 %/°C
EC to TDS Conversion Factor0.40 to 1.00
Reference Temperature15°C, 20°C and 25°C
EC/TDS Multi-range Measurement Modesautorange, autoend, lock and fixed range
Salinity (% NaCl) Range0.0 to 400.0%
Salinity (% NaCl) Resolution0.1%
Salinity (% NaCl) Accuracy±1% of reading
Salinity (% NaCl) Calibrationmax. one point only in % range (with HI7037 standard)
Salinity (PSU) Range0.00 to 42.00 (PSU)
Salinity (PSU) Resolution0.01 PSU
Salinity (PSU) Accuracy±1% of reading
Salinity (PSU) Calibrationbased on conductivity calibration
Salinity Range0.00 to 80.00 (ppt)
Salinity Resolution (ppt)0.01 ppt
Salinity Accuracy (ppt)±1% of reading
Salinity Calibration (ppt)based on conductivity calibration
Resistivity Range1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy±1% of reading (±10 Ω or 1 digit, whichever is greater)
Temperature Range-20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy±0.2°C; ±0.4°F (excluding probe error)
EC/TDS ProbeHI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)
Logging TypeLog-on-demand
Logging Memoryup to 10
Connectivityopto-isolated USB with optional HI 92000 software and micro USB cable
Automatic Shut-Offuser selectable
Battery Type/Life1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Environment0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight400 g (14.2 oz.)
Ordering InformationHI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.
Notes*The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe